Nevada State Contractors Board • PSI Trade Exam • 60 Questions • 2 Hours • 75% Passing • 2018 IBC • Roofing • Siding • Waterproofing
Ready to become a licensed Nevada Roofing and Siding Contractor? This comprehensive guide explains Nevada C-15 licensing requirements, PSI examination details, the official study categories, roofing and siding installation concepts, safety, waterproofing, business and law preparation, and related books from Contractor Exam Preps.
Roofing and siding contractors play an important role in protecting buildings from weather, moisture, and everyday wear.
In Nevada, contractors work on residential homes, apartment buildings, retail centers, office buildings, industrial properties, and other structures.
Even though Nevada has plenty of sunshine, roofs and exterior walls still face demanding conditions.
High temperatures, ultraviolet exposure, wind, occasional heavy rain, and temperature changes can all affect building materials.
When a roof leaks, nobody wants to hear that the contractor thought flashing was merely decorative trim!
Good roofing and siding work requires understanding the entire building envelope.
The roof deck, underlayment, roof covering, penetrations, flashings, drainage, exterior walls, siding, and weather barriers must work together.
Contractors must understand proper installation, repairs, material compatibility, construction safety, and applicable building-code requirements.
The Nevada C-15 examination measures knowledge across many of these subjects.
C-15 Roofing and Siding is a Nevada specialty contractor classification issued by the Nevada State Contractors Board.
It covers work authorized under the C-15 roofing and siding subclassifications, including applicable insulation and waterproofing work.
The classification includes installation, alteration, application, and repair of roofing materials used to make buildings watertight and weatherproof.
It also covers appropriate siding installation, alteration, and repair to protect exterior walls.
Roofing materials can include shingles, shakes, tile, slate, metal, and other approved roof systems.
Siding materials may include wood, metal, plastic, and other recognized exterior wall coverings.
The exact legal scope is governed by Nevada's contractor classification rules.
The primary C-15 classification is broader than the C-15A Roofing subclassification.
C-15A focuses on roofing work.
C-15 includes roofing and siding along with other work covered by its related subclassifications.
The distinction is important for examination preparation.
A candidate studying only shingles and roof repairs may overlook siding questions, exterior wall weatherproofing, flashing, and photovoltaic roof components.
The full C-15 trade examination includes those subjects.
The Nevada State Contractors Board administers contractor licensing in Nevada.
The Board reviews applications, qualifications, work experience, financial responsibility, and other licensing requirements.
It determines whether applicants are eligible to take the required examinations.
After approval, candidates receive examination eligibility instructions.
PSI administers the C-15 Roofing and Siding trade examination.
Applicants also generally must satisfy the Nevada Contractor Management Survey examination, also known as the CMS business and law exam.
Both the trade and business components are part of the broader licensing process, subject to applicable exemptions or waivers.
The Nevada C-15 Roofing and Siding Contractor trade examination contains 60 scored questions.
Candidates have two hours, or 120 minutes, to complete the examination.
The passing requirement is 45 correct answers.
That equals a 75% passing score.
On average, candidates have two minutes per scored question.
Some questions can be answered quickly from trade experience.
Others may require looking up information in the approved building code reference.
PSI may include additional unscored experimental questions, depending on the current examination bulletin.
Candidates should answer every question carefully because experimental questions are not identified during the examination.
Yes. The C-15 trade examination is open book, but it has specific reference restrictions.
The current listed exam-room reference is the 2018 International Building Code.
Roofing manuals, OSHA books, construction estimating texts, siding installation standards, and photovoltaic roofing publications are study references.
They are not automatically permitted inside the C-15 trade examination room.
This distinction matters.
The Nevada C-15 Roofing and Siding Exam Book Package contains both the approved 2018 IBC and supplemental technical roofing and siding books.
Candidates should practice using the IBC to locate relevant code provisions and use the other publications to develop knowledge before test day.
The current C-15 examination outline includes nine technical categories.
The nine categories total 60 scored questions.
Steep Roofing is the largest examination category, with 16 questions.
Roofing Substrates and Siding each contain eight questions.
Elastomeric Roofing and Built-Up Bituminous Roofing contain seven questions each.
That means candidates should understand both steep-slope and low-slope roof systems.
Steep-slope roofing is the largest subject on the exam.
Students should review asphalt shingles, wood shakes, wood shingles, tile, slate, metal roof coverings, underlayments, fastening, roof decks, and installation practices.
Study roof edges, ridges, hips, valleys, penetrations, and roof transitions.
Understand the purpose of flashing and how roofing components move water away from the structure.
Review manufacturer instructions and applicable code provisions.
The Roofing Construction and Estimating book offers useful study on steep roofing, roofing materials, installation, and project estimating.
The roof substrate supports the roofing assembly.
A roof covering cannot perform properly if the underlying surface is damaged, unstable, or unsuitable.
Candidates should review roof sheathing, deck materials, moisture problems, substrate deterioration, attachment, and preparation.
Learn to recognize conditions that require repair before installing a new roof system.
Study the relationship between roof slope, substrate condition, drainage, and roofing material compatibility.
Roof substrates account for eight questions on the current C-15 blueprint.
Low-slope commercial roofs often use membrane or coating systems rather than conventional shingles.
Students should study elastomeric roofing systems, membrane performance, seams, attachment, waterproofing, and roof drainage.
Know why the correct application method and substrate preparation matter.
Review common causes of leaks and system failures.
Understand how flashing connects the membrane to roof edges, penetrations, and adjacent construction.
Built-up roofing uses multiple layers of roofing materials designed to create a weather-resistant roof system.
Students should understand asphaltic materials, reinforcing plies, surfacing, installation practices, and repairs.
Review how low-slope roof design influences drainage and waterproofing.
Learn to identify common installation problems and maintenance requirements.
The C-15 exam includes seven questions in the Built-Up Bituminous Roofing category.
Roof repair questions may involve identifying damage, choosing repair methods, and recognizing the cause of water intrusion.
Students should understand aging roofing materials, punctures, failed flashing, damaged shingles, membrane defects, and drainage problems.
A leak inside a building does not always mean that the water entered directly above the stain.
Water can travel along roof components before becoming visible.
Good troubleshooting requires examining the complete roof assembly.
Siding is a major part of the Nevada C-15 examination.
The current outline contains eight siding questions.
Students should study the installation of wood, metal, plastic, and related exterior siding materials.
Review fasteners, joints, trim, corners, soffits, and transitions.
Understand the importance of water-resistive barriers, flashing, and weatherproofing.
Exterior wall coverings must work with windows, doors, roof edges, and other building-envelope components.
The ASTM D4756 standard is a useful technical study reference for rigid PVC siding and soffit installation.
It is included in the Nevada C-15 technical book package for study but is not listed as an allowed trade-exam-room reference.
Sheet metal and flashing help direct water away from vulnerable areas.
Students should review step flashing, counterflashing, valley flashing, roof edges, drip edges, and penetration details.
Study how metal components connect roof coverings and exterior wall materials.
Learn why poor flashing can cause leaks even when the main roofing material is installed correctly.
The C-15 examination includes three questions specifically assigned to Sheet Metal and Flashing.
Modern roofs may include solar panels, mounting systems, or photovoltaic roof tiles.
The current C-15 examination includes two questions about Photovoltaic Systems.
Roofing contractors should understand how rooftop solar equipment can affect weatherproofing, penetrations, mounting, flashing, and maintenance access.
Photovoltaic roofing work may also require coordination with appropriately licensed electrical or solar contractors.
A roofing contractor should not assume that C-15 automatically authorizes separate electrical installations.
Roofing work involves significant fall and jobsite hazards.
Safety is one of the official examination categories.
Students should review fall protection, ladders, scaffolds, personal protective equipment, tools, material handling, and hazard recognition.
Study OSHA construction safety principles, including applicable fall-protection requirements.
High temperatures and sun exposure are also important practical concerns for Nevada roofers.
Work planning should account for weather, heat, worker safety, and safe roof access.
Roofing contractors must estimate materials accurately.
Study roof area, slope, waste factors, underlayment quantities, flashing lengths, fasteners, labor, and demolition costs.
A roofing square equals 100 square feet of roof area.
However, the actual surface area of a sloped roof may be larger than the horizontal footprint.
Estimating also must consider waste, special materials, roof penetrations, difficult access, and disposal.
The Roofing Construction and Estimating reference provides examples and methods for roofing takeoffs and estimates.
The Nevada State Contractors Board generally requires a trade qualifying individual with four years of qualifying experience within the previous 15 years.
Acceptable experience may include journeyman, foreman, supervising employee, or contractor work within the requested classification.
The Board may accept qualifying education or training toward a portion of the experience requirement under its rules.
Applicants should review the current contractor application for documentation requirements and any applicable exceptions.
Experience must be relevant to C-15 Roofing and Siding, not merely general construction work.
The Nevada State Contractors Board currently lists a $300 application processing fee.
The Board also lists a $600 biennial license fee after approval.
Applicants must meet applicable financial responsibility requirements.
Contractor license bonds are set individually by the Board.
The Board's published general bond range is $1,000 to $500,000, depending on the applicant's circumstances.
That does not mean every C-15 contractor must post the same bond.
The required amount is communicated during the licensing process.
Workers' compensation compliance or an appropriate exemption may also be required.
Start with the official PSI C-15 examination outline.
Confirm the approved 2018 International Building Code reference.
Study steep roofing, roofing substrates, siding, elastomeric roofing, built-up roofing, repairs, flashing, photovoltaic components, and safety.
Review the applicable roofing manuals and estimating books as technical study references.
Practice locating roofing and exterior wall provisions in the IBC.
Complete timed practice questions using the 60-question, two-hour examination format.
Review missed questions and repeat your weakest categories.
Study the Nevada CMS business and law requirements separately.
With a clear plan and suitable references, preparing for C-15 can be much more manageable.
Important Nevada C-15 Roofing and Siding 2026 Update: Nevada C-15 is a licensed specialty contractor classification administered by the Nevada State Contractors Board. PSI administers the C-15 trade examination. The current trade exam contains 60 scored questions, has a two-hour time limit, and requires 45 correct answers to pass. The examination is open book, but the 2018 International Building Code is the listed permitted trade-exam reference. Other roofing and siding publications are for study only. The current exam outline contains nine categories, including Steep Roofing, Roofing Substrates, Siding, and Photovoltaic Systems. Contractor applicants generally need four years of relevant experience within the preceding 15 years and must complete applicable business and law, application, financial, and bond requirements. Always check the current PSI bulletin before testing.
A Nevada C-15 Roofing and Siding Contractor is a licensed specialty contractor authorized to perform work within Nevada's roofing and siding classification.
The classification includes appropriate roofing installation, alteration, application, and repair.
It also includes siding work used to protect exterior walls from weather and moisture.
The primary C-15 classification encompasses work from its related roofing, siding, insulation, and waterproofing subclassifications, subject to Nevada regulations.
C-15 is a business contractor license, not an individual journeyman trade card.
The Nevada State Contractors Board issues the license after the applicant meets the applicable requirements.
State: Nevada.
Classification: C-15 Roofing and Siding.
Licensing agency: Nevada State Contractors Board.
Trade testing provider: PSI.
Related subclassification: C-15A Roofing.
Core work: Roofing, siding, insulation, and waterproofing within the legal classification scope.
| Step or Requirement | Nevada Information | What to Prepare |
|---|---|---|
| State | Nevada | Confirm C-15 fits the intended work. |
| License Classification | C-15 | Roofing and Siding. |
| Licensing Agency | Nevada State Contractors Board | Use the official contractor application. |
| Trade Examination | Roofing and Siding Contractor | Review the C-15 PSI outline. |
| Testing Provider | PSI | Schedule after eligibility approval. |
| Scored Questions | 60 | Practice 60-question tests. |
| Exam Time | Two Hours | Practice 120-minute sessions. |
| Passing Requirement | 45 Correct | Target more than 75%. |
| Passing Percentage | 75% | Know all nine categories. |
| Exam Format | Open Book, Restricted References | Follow PSI testing rules. |
| Trade Exam Reference | 2018 International Building Code | Use the approved edition. |
| NRCA Manuals in Exam | Not Allowed as Trade References | Study before testing. |
| OSHA Reference in Trade Exam | Study Only | Learn safety concepts beforehand. |
| Siding ASTM Reference | Study Only | Review PVC siding and soffit installation. |
| General Business Examination | Contractor Management Survey | Study Nevada business and law. |
| CMS Reference | Construction Business and Law Manual for Nevada | Prepare for separate CMS exam. |
| Qualifying Individual | Trade Experience Required | Document relevant C-15 experience. |
| Experience Period | Four Years | Within preceding 15 years generally. |
| Application Processing Fee | $300 | Submit with application. |
| Biennial License Fee | $600 | Pay after applicable approval. |
| Financial Responsibility | Required | Prepare financial documents. |
| Contractor License Bond | Board Determines Amount | Follow approval letter. |
| Published General Bond Range | $1,000 to $500,000 | Not a fixed C-15 bond. |
| Workers' Compensation | Applicable Compliance or Exemption | Follow Board instructions. |
| Roofing Only Subclassification | C-15A | Different from full C-15. |
| Siding Work | Included in Full C-15 | Study exterior wall systems. |
| Photovoltaic Roofing | Specific Exam Subject | Review roof integration and flashing. |
| Final License Issuance | Board Approval | Complete all remaining conditions. |
| Detail | Category | Published Information |
|---|---|---|
| Examination | Trade | Nevada Roofing and Siding Contractor |
| Classification | License | C-15 |
| Licensing Board | Authority | Nevada State Contractors Board |
| Testing Provider | Testing | PSI |
| Scored Questions | Format | 60 |
| Time | Format | 120 Minutes |
| Passing Score | Scoring | 45 Correct / 75% |
| Trade Exam Type | Testing | Open Book, Limited References |
| Permitted Trade Book | Reference | 2018 International Building Code |
| Safety | Blueprint | 5 Questions |
| Roofing Substrates | Blueprint | 8 Questions |
| Steep Roofing | Blueprint | 16 Questions |
| Roofing Repairs | Blueprint | 4 Questions |
| Elastomeric Roofing | Blueprint | 7 Questions |
| Built-Up Bituminous Roofing | Blueprint | 7 Questions |
| Sheet Metal and Flashing | Blueprint | 3 Questions |
| Siding | Blueprint | 8 Questions |
| Photovoltaic Systems | Blueprint | 2 Questions |
| Total Blueprint | Blueprint | 60 Questions |
| Business and Law | Separate Exam | Contractor Management Survey |
| Business Reference | CMS | Construction Business and Law Manual for Nevada |
| Qualifying Experience | Licensing | Four Years Within Previous 15 Years Generally |
| Application Fee | Licensing | $300 |
| Biennial License Fee | Licensing | $600 |
| Bond | Licensing | Board-Determined |
| Full C-15 Scope | Trade | Roofing, Siding and Related Authorized Work |
| C-15A | Subclass | Roofing Only |
| Main Study Book | Store | Nevada C-15 Exam Book Package |
| Focused Rental | Store | Exam-Room Approved Books and Course |
Trade exam: 60 scored questions.
Time: Two hours.
Passing: 45 correct answers.
Reference: International Building Code, 2018.
Separate requirement: Nevada CMS business and law examination where applicable.
Fall protection, ladders, scaffolds, power tools, protective equipment, material handling, and roofing jobsite safety.
Roof decks, sheathing, structural support, deterioration, surface preparation, moisture conditions, and attachment.
Shingles, shakes, tile, slate, metal roofing, roof slopes, underlayments, fasteners, valleys, ridges, and installation details.
Leak diagnosis, damaged coverings, failed seams, flashing defects, and repair methods.
Flexible membrane systems, waterproofing, seams, coatings, insulation, attachment, and maintenance.
Bituminous materials, reinforcing plies, surfacing, application techniques, drainage, and repairs.
Flashings, roof edges, valleys, penetrations, counterflashing, and sheet metal components.
Exterior siding systems, soffits, fasteners, flashing, weather-resistant construction, and installation principles.
Rooftop photovoltaic components, mounting, penetrations, flashing, and roof assembly integration.
Largest category: Steep Roofing, 16 questions.
Second tier: Roofing Substrates and Siding, eight questions each.
Both low-slope systems: Elastomeric and Built-Up Bituminous Roofing, seven questions each.
Total: 60 scored questions.
Start by reviewing the current PSI C-classification examination information.
Confirm that C-15 Roofing and Siding matches the license you are applying for.
Obtain the 2018 International Building Code listed for exam-room use.
Learn how to locate roofing, exterior wall, and building-envelope requirements.
Review roofing substrates and steep-slope materials.
Study shingles, tile, slate, shakes, and metal roofing.
Practice recognizing roof flashing and drainage details.
Study elastomeric roofing and built-up bituminous systems.
Review roofing repairs, including leaks and damaged materials.
Practice siding installation questions and ASTM D4756 concepts.
Study photovoltaic roof attachments and waterproofing considerations.
Review OSHA roofing safety and fall protection.
Practice roof measurements and material estimating.
Take mixed 60-question tests using a two-hour limit.
Review incorrect answers by examination category.
For a comprehensive Nevada-focused reference package, review the Nevada C-15 Exam Book Package.
For a more focused approved-reference option, review the Nevada C-15 Exam-Room Rental Package.
Step 1: Review the PSI C-15 exam outline.
Step 2: Learn the 2018 IBC.
Step 3: Study all nine roofing and siding categories.
Step 4: Use technical references for study only.
Step 5: Complete timed practice and CMS business preparation.
A reliable building envelope depends on the relationship between roofing materials, roof substrates, flashing, water control, and siding.
This educational diagram illustrates a simplified roof-to-wall assembly.
Simplified educational illustration, not a construction detail. Real assemblies require suitable materials, manufacturer instructions, local code compliance, and approved plans.
Make sure Roofing and Siding matches the business work you intend to perform. Do not confuse C-15 with C-15A Roofing.
Determine who will demonstrate the relevant experience and oversee work in the classification.
Prepare proof of four years of qualifying work within the applicable preceding period, generally 15 years.
Complete the Board's application and supporting documents. Pay the applicable processing fee.
Wait for the Board's approval and follow the authorized testing instructions.
Study roofing, siding, safety, the 2018 IBC, and the separate Nevada business and law materials.
For the C-15 trade exam, target at least 45 correct answers out of 60 within two hours.
Submit the Board-required bond, financial information, workers' compensation documentation or exemption, and license fees before issuance.
These values correspond to the current 60-question C-15 trade-examination outline.
Total: 60 scored questions.
Largest subject: Steep Roofing.
Significant additional topics: Roof Substrates, Siding, Elastomeric Roofing, and Built-Up Roofing.
Important: Percentages are rounded; question counts are the controlling totals.
The Nevada C-15 trade examination permits the listed 2018 International Building Code under PSI rules.
Other important books can help candidates study roofing, siding, waterproofing, photovoltaic components, safety, and estimating before entering the testing center.
| Reference Book | Edition | Examination Use |
|---|---|---|
| International Building Code | 2018 | Allowed C-15 trade exam reference. |
| NRCA Roofing Manual: Steep Slope Roof Systems | 2025 | Study only. Steep roofing materials and installation. |
| NRCA Roofing Manual: Metal Panel and SPF Roof Systems | 2024 | Study only. Metal and SPF roofing. |
| NRCA Roofing Manual: Membrane Roofing Systems | Applicable Store Edition | Study only. Low-slope roofing systems. |
| OSHA Construction Safety and Health Standards | 29 CFR Part 1926 | Study only. Jobsite safety and fall protection. |
| ASTM D4756 PVC Siding and Soffit | Applicable Edition | Study only. Siding installation standards. |
| Roofing Construction and Estimating | Daniel Atcheson | Study only. Materials, estimating, and installation. |
| Carpentry and Building Construction | 2016 | Study only. Roof framing, sheathing, and substrates. |
| NRCA Guidelines for Roof Systems With Rooftop Photovoltaic Components | 2018 | Study only. Rooftop PV integration. |
| Construction Business and Law Manual for Nevada | Current PSI-Listed Edition | Separate CMS business examination reference. |
| PSI C-Classification Examination Bulletin | Current | Official exam rules, allowed references, and outline. |
Trade examination: 2018 International Building Code.
CMS business and law examination: Construction Business and Law Manual for Nevada, subject to current PSI instructions.
Technical study books: NRCA manuals, OSHA, ASTM, Roofing Construction and Estimating, carpentry, and photovoltaic guidelines.
Do not bring study-only books into the C-15 trade exam unless PSI expressly authorizes them.
The Nevada C-15 trade examination is open book, but the reference rules are strict.
Use the approved 2018 International Building Code to practice roofing and exterior wall code navigation.
Learn the table of contents, index, major building-envelope topics, and relevant definitions.
Read complete sections, including exceptions and table notes.
Study roofing systems, siding materials, safety, and repairs in separate technical books before the exam.
Do not depend on those books being available during testing.
With 60 scored questions and two hours, time management matters.
Answer familiar questions efficiently.
Use the IBC when code confirmation is needed.
Mark difficult questions and return to them when possible.
Within the applicable classification scope, Nevada C-15 covers installation, application, alteration, and repair of roofing systems and exterior siding.
Roofing work may involve approved shingles, shakes, tile, slate, metal systems, membranes, and other weatherproof materials.
Siding work involves exterior wall coverings designed to protect buildings against the elements.
The primary C-15 classification also encompasses authorized work from related insulation and waterproofing subclassifications.
The exact scope must be evaluated under Nevada regulations and the license issued by the Board.
Electrical connections, unrelated structural alterations, and other specialty work may require separate licensed contractors.
Contractors should confirm project-specific permits, inspections, and local building rules.
Classification: C-15 Roofing and Siding.
Roofing: Weatherproof roofing systems and repairs.
Siding: Exterior wall cladding and weather protection.
Related work: Authorized insulation and waterproofing within the classification.
Restrictions: Other specialty activities may require additional licensing.
| Classification | Primary Focus | Main Distinction |
|---|---|---|
| C-15 Roofing and Siding | Roofing, siding, and authorized related subclassification work. | Broad primary specialty classification. |
| C-15A Roofing | Roofing materials and associated roof work. | Narrower roofing subclassification. |
| C-15B Siding | Exterior siding. | Narrower siding subclassification. |
| Other C-15 Subclassifications | Insulation and waterproofing as defined by Nevada rules. | Scope depends on specific subclassification. |
| B General Building | General building projects. | Different licensing and trade examination requirements. |
| B-2 Residential and Small Commercial | Qualifying residential and small commercial building projects. | Not the same examination as C-15. |
| C-2 Electrical Contracting | Electrical contracting work. | Separate authorization for electrical installations. |
| Contractor Management Survey | Nevada business and law. | Separate examination component, not a roofing classification. |
60 Questions • 2 Hours • 75% Passing
Nevada State Contractors Board
After Examination and Board Review
This schedule follows the official trade-examination subjects and includes preparation for the separate business and law examination.
The Nevada C-15 examination can be challenging because it covers several different roofing systems and exterior siding work.
Someone experienced in asphalt shingles may know steep roofing very well.
However, the examination also includes elastomeric roofing, built-up bituminous systems, siding, flashing, repairs, substrates, safety, and photovoltaic systems.
The examination contains 60 scored questions, and candidates have two hours.
They must answer 45 questions correctly.
Because only the listed 2018 IBC may be used as the trade reference, candidates must learn much of the technical content before testing.
Steep Roofing accounts for 16 questions.
Roofing Substrates and Siding each contribute eight.
Low-slope roofing subjects also make up a significant part of the examination.
Consistent study and mixed practice help candidates prepare.
The Nevada C-15 Exam Book Package covers the major technical subjects.
The Roofing Construction and Estimating book helps reinforce installation and estimating principles.
Contractor Exam Preps offers Nevada-specific C-15 book packages, prepared book rentals, online course options, and individual roofing references.
The products below are directly related to Nevada Roofing and Siding contractor preparation.
Complete Technical Reference Collection
Important: Only the 2018 International Building Code is listed as permitted for the C-15 trade examination. The other books are for technical study.
Focused Reference Rental • Business Law • Course Access
Important: This package combines the allowed C-15 trade reference with the separate CMS business reference. Follow PSI rules for each examination.
Trade Study • Licensing Support • Business Preparation
Important: Review the product page for its current included services, availability, fulfillment conditions, and pricing. Purchasing services does not guarantee licensing.
Comprehensive roofing and siding study: Nevada C-15 Exam Book Package.
Focused approved-reference preparation: Nevada C-15 Exam-Room Rental.
Licensing and business assistance: Nevada C-15 All-Inclusive Package.
Individual supplemental text: Roofing Construction and Estimating.
Current prices and availability: Check product pages.
Nevada Roofing, Siding, Waterproofing, PSI Testing and Licensing Topics
• Nevada State Contractors Board
• Nevada C-15 Roofing and Siding
• Nevada C-15A Roofing
• PSI Roofing and Siding Trade Exam
• 60 Scored Questions
• Two-Hour Examination
• 45 Correct to Pass
• 75% Passing Score
• Open-Book Examination
• International Building Code 2018
• Roofing Substrates
• Roof Decks
• Roof Sheathing
• Roof Framing
• Roof Underlayment
• Steep-Slope Roofing
• Asphalt Shingles
• Wood Shakes
• Wood Shingles
• Tile Roofing
• Slate Roofing
• Metal Roofing
• Roof Pitch
• Roof Valleys
• Roof Hips
• Roof Ridges
• Roof Penetrations
• Roof Repairs
• Leak Diagnosis
• Roof Maintenance
• Low-Slope Roofing
• Elastomeric Roofing
• Built-Up Bituminous Roofing
• Roofing Membranes
• Membrane Seams
• Roof Surfacing
• Roof Coatings
• Spray Polyurethane Foam
• Roofing Insulation
• Roof Drainage
• Moisture Protection
• Waterproofing Systems
• Water-Resistive Barriers
• Sheet Metal
• Step Flashing
• Counterflashing
• Valley Flashing
• Drip Edges
• Roof Edge Details
• Exterior Wall Siding
• Wood Siding
• Aluminum Siding
• Steel Siding
• PVC Siding
• ASTM D4756
• Siding Fasteners
• Siding Trim
• Siding Joints
• Exterior Wall Weatherproofing
• Fascia
• Soffits
• Photovoltaic Roof Systems
• Solar Panel Mounting
• Photovoltaic Roof Flashing
• OSHA Construction Safety
• Fall Protection
• Ladder Safety
• Scaffold Safety
• Personal Protective Equipment
• Roof Measurements
• Roofing Squares
• Roof Slope Calculations
• Material Takeoffs
• Roofing Waste Factors
• Labor Estimating
• Roofing Construction and Estimating
• NRCA Roofing Manuals
• Carpentry and Building Construction
• Nevada Contractor Application
• Four Years Qualifying Experience
• Nevada Contractor Management Survey
• Nevada Business and Law
• Financial Responsibility
• Contractor License Bond
• Workers' Compensation Compliance
• Contractor Exam Preps Study Books
• Nevada C-15 Reference Rental
• Nevada C-15 Exam Preparation Course
• Timed Trade Practice Questions
Nevada C-15 Contractor Licensing
It is a Nevada specialty contractor license covering roofing and siding work and related work authorized under the classification's subclassifications.
The Nevada State Contractors Board issues C-15 licenses after applicants complete applicable qualification and licensing requirements.
C-15 is the broader Roofing and Siding classification. C-15A is the narrower Roofing subclassification.
Yes. Exterior siding is part of the C-15 classification and a separate examination subject.
The primary C-15 classification encompasses authorized insulation and waterproofing work within its related subclassifications. Review the Nevada classification rules for exact boundaries.
PSI Roofing and Siding Examination
The current C-15 trade examination contains 60 scored questions.
Candidates have two hours, or 120 minutes, to complete the trade exam.
Candidates must answer 45 of 60 scored questions correctly, which equals 75%.
Yes. It is an open-book trade examination with specific reference restrictions. The listed permitted trade reference is the 2018 International Building Code.
The 2018 International Building Code is the listed exam-room-approved reference. Follow PSI's current book-condition and marking rules.
The NRCA manuals in the Nevada C-15 package are study-only materials and are not listed for use inside the C-15 trade examination room.
Contractor applicants generally must pass the Contractor Management Survey business and law examination as well as the applicable trade examination, unless a valid waiver applies.
Roofing and Siding Examination Subjects
Steep Roofing is the largest individual subject, with 16 scored questions.
The current examination outline contains eight siding questions.
Study asphalt shingles, wood shingles and shakes, tile, slate, metal roofing, roof underlayments, membranes, and other relevant roofing materials.
It covers roof decks, sheathing, preparation, deterioration, moisture conditions, attachment, and other supporting components.
Yes. Elastomeric Roofing accounts for seven questions on the current C-15 outline.
Yes. Built-Up Bituminous Roofing accounts for seven examination questions.
Yes. Roofing Repairs contains four questions.
Flashing protects roof edges, penetrations, valleys, and roof-to-wall transitions by helping direct water away from vulnerable areas.
Yes. The current C-15 trade blueprint includes two Photovoltaic Systems questions relating to rooftop components and their interaction with roof assemblies.
Yes. ASTM D4756 is included in the Nevada C-15 book package as a study reference for rigid PVC siding and soffit installation.
Safety is an official examination subject. Candidates should understand roofing fall hazards, ladders, scaffolds, protective equipment, and related jobsite practices.
Nevada Contractor Licensing and Fees
The trade qualifying individual generally must demonstrate four years of relevant experience within the 15 years before application, subject to Board rules and exceptions.
The Nevada State Contractors Board may accept qualifying education and training toward part of the experience requirement under its rules. Confirm the amount and documentation with the Board.
The Nevada State Contractors Board currently lists a $300 application processing fee.
The Board currently lists a $600 biennial license fee. Other examination, bond, and related costs may apply.
Yes. The Board determines the required contractor license bond based on the applicant and licensing circumstances. The bond amount is not one fixed figure for every C-15 business.
No. The applicant must also complete other applicable Board requirements, including financial responsibility, bonding, workers' compensation compliance, and required licensing payments.
Contractor Exam Preps Roofing Books
Yes. The Nevada Roofing and Siding Contractor C-15 Exam Book Package includes the 2018 IBC and supplemental roofing, siding, safety, estimating, carpentry, and photovoltaic references.
Yes. The store lists a Nevada C-15 Exam-Room Approved Books and Course Rental package containing the IBC 2018, Nevada business and law reference, and course access. Check current availability and rental conditions.
It is a technical roofing reference by Daniel Atcheson covering roofing systems, materials, installations, measurements, estimating, and maintenance.
Yes. They are useful technical study references for roofing systems. They are not listed as permitted books inside the Nevada C-15 trade examination.
No. Exam preparation products support learning, but passing the PSI examination and receiving a contractor license depend on the candidate and the applicable licensing authority.
Watch this roofing-focused 1ExamPrep video about contractor examination preparation, roofing references, open-book study, roofing safety, and testing strategies.
The video is specifically about Mississippi roofing licensing, so its state-specific license details and passing requirements are not Nevada rules.
However, the roofing study methods, reference-navigation advice, and technical preparation topics are useful for Nevada C-15 Roofing and Siding candidates.
Nevada reminder: The Nevada C-15 trade exam has 60 scored questions, allows two hours, requires 45 correct answers, and permits the listed 2018 IBC trade reference.
Creator: 1ExamPrep.
Video: How to Pass the Mississippi Roofing Contractor Exam.
Related subjects: Roofing safety, trade exam preparation, study references, and open-book testing strategies.
Nevada-specific study requirement: PSI C-15 outline and 2018 IBC.
Important: Do not use Mississippi licensing rules for a Nevada C-15 application.
Use the Nevada State Contractors Board and PSI for official licensing, application, examination, and approved-reference requirements.
Use Contractor Exam Preps for roofing and siding books, approved-reference preparation, courses, and licensing support resources.
Licensing: Nevada State Contractors Board.
Trade examination: PSI C-15 Roofing and Siding.
Exam details: 60 questions, two hours, 45 correct to pass.
Exam-room trade reference: 2018 International Building Code.
Business and law: Separate Contractor Management Survey.
Technical references: Roofing, siding, safety, estimating, and photovoltaic books.
Preparing for the Nevada C-15 Roofing and Siding Contractor examination is an important step for construction professionals who want to become licensed in this specialty trade.
Roofs and exterior walls protect buildings from weather and moisture.
When these systems are installed correctly, they support the long-term performance of homes, commercial buildings, offices, warehouses, and other structures.
When roofing or siding systems fail, the consequences can include leaks, damaged materials, and expensive repairs.
That is why contractors need to understand proper materials, installation methods, building codes, and safety requirements.
Nevada's C-15 Roofing and Siding classification is administered by the Nevada State Contractors Board.
The classification covers roofing and siding work and authorized related work under its subclassifications.
It is broader than the narrower C-15A Roofing subclassification.
Applicants should understand which classification matches their intended business activities.
The Nevada C-15 trade examination is administered through PSI.
It contains 60 scored questions.
Candidates have two hours to complete the test.
The passing requirement is 45 correct answers, equivalent to 75%.
The examination is open book, but it has strict reference limits.
The listed exam-room trade reference is the 2018 International Building Code.
Other roofing manuals, siding standards, OSHA publications, estimating books, and photovoltaic references are valuable study tools but are not approved C-15 trade-exam-room books.
Students should learn to use the 2018 IBC effectively.
Practice locating roofing provisions, exterior wall requirements, construction definitions, tables, and exceptions.
Good reference navigation can help save time during the examination.
The current C-15 examination outline contains nine major technical categories.
Steep Roofing is the largest subject, with 16 questions.
Roofing Substrates and Siding each contain eight questions.
Elastomeric Roofing and Built-Up Bituminous Roofing each contain seven.
The remaining questions cover Safety, Roofing Repairs, Sheet Metal and Flashing, and Photovoltaic Systems.
These categories show that C-15 candidates need broad roofing and exterior wall knowledge.
Studying only asphalt shingles is not enough.
Students should review tile, slate, wood shingles, wood shakes, metal roofing, roof underlayments, fastening, and drainage.
They should also understand roof decks and substrates.
A roof covering depends on the supporting surface.
Damaged decking, moisture problems, poor attachment, or incorrect preparation can create problems throughout the roofing assembly.
Low-slope roofing is another important study area.
Candidates need to understand elastomeric roofing, built-up bituminous systems, membranes, seams, coatings, surfacing, and repairs.
Roofing systems must move water effectively while protecting vulnerable areas.
Flashing is particularly important at valleys, edges, penetrations, and roof-to-wall transitions.
Siding also deserves dedicated study time.
Exterior wall systems use materials such as wood, metal, and plastic.
Installation details may involve fasteners, corners, joints, trim, soffits, and weather-resistant barriers.
Understanding how siding connects with roofing and flashing helps candidates recognize proper building-envelope construction.
Photovoltaic roofing is included in the examination.
Contractors should understand roof penetrations, mounting, waterproofing, and coordination with other licensed trades.
Safety is another required examination subject.
Roofing involves fall hazards, ladders, scaffolds, power tools, and other jobsite risks.
Students should understand appropriate safety practices and recognize unsafe working conditions.
Roofing estimating is valuable for business operations.
Contractors must measure roof areas, estimate materials, account for waste, evaluate labor, and understand project costs.
Accurate estimates help reduce costly mistakes and support professional contracting.
The Nevada contractor license application includes additional requirements beyond passing the trade examination.
The Nevada State Contractors Board generally requires a trade qualifying individual with four years of relevant experience within the preceding 15 years.
Applicants must also complete the contractor application and applicable business and law examination.
The Board currently lists a $300 application processing fee and a $600 biennial license fee.
Financial responsibility, contractor bonding, and workers' compensation requirements may also apply.
The license is issued only after all applicable conditions have been satisfied.
Contractor Exam Preps offers several products relevant to Nevada C-15 preparation.
The Nevada C-15 Roofing and Siding Exam Book Package includes the permitted 2018 IBC and supplemental roofing, siding, safety, estimating, carpentry, and photovoltaic references.
The store also offers a focused exam-room reference rental package with the 2018 IBC and Nevada business and law manual.
Students can also explore the Roofing Construction and Estimating book and NRCA Roofing Manual Book Set.
Each resource serves a different study purpose.
Technical references help develop roofing knowledge, while the IBC supports open-book code navigation.
A six-week study schedule can make preparation more manageable.
Start with licensing rules and safety.
Then review steep roofing, substrates, low-slope systems, repairs, siding, flashing, and photovoltaic systems.
Include estimating, IBC navigation, and CMS business and law study.
Finish with timed 60-question practice sessions.
Review incorrect answers and repeat weak subjects.
The best preparation combines practical experience, appropriate references, and steady study.
With the correct licensing information and a focused plan, Nevada C-15 candidates can approach the examination with stronger knowledge and improved confidence.
Nevada C-15 Roofing and Siding Contractor Exam Prep helps contractor applicants understand the trade examination, licensing requirements, and technical knowledge needed for Nevada's Roofing and Siding specialty classification.
The Nevada State Contractors Board administers the C-15 license. This classification covers roofing, siding, and related work authorized within the classification's scope. It is broader than the C-15A Roofing subclassification because it includes additional exterior wall and related work.
Roofing and siding contractors install, alter, repair, and maintain systems that protect buildings from weather and moisture. Their work may involve roof coverings, underlayments, decks, membranes, flashing, siding, soffits, fascia, waterproofing, and related components.
Applicants for Nevada C-15 licensing must satisfy the Board's qualification requirements. The trade qualifying individual generally needs four years of relevant work experience within the 15 years preceding the application. The Board may recognize qualifying education or training under its rules.
The Nevada contractor application includes an application processing fee, proof of qualifications, financial responsibility documents, and other required information. The Board currently lists a $300 application fee and a $600 biennial license fee. The required contractor license bond is determined by the Board for the applicant.
Contractor applicants generally must complete a trade examination and the separate Contractor Management Survey business and law examination. PSI administers the required examinations after the Nevada State Contractors Board determines examination eligibility.
The Nevada C-15 Roofing and Siding trade examination contains 60 scored questions. Candidates have two hours to complete the test. The minimum passing requirement is 45 correct answers, which equals 75%.
The examination is open book, but the permitted reference list is limited. The 2018 International Building Code is the listed exam-room-approved trade reference. Candidates should confirm the current PSI rules before testing.
The C-15 examination covers nine technical categories. Steep Roofing is the largest, with 16 questions. Roofing Substrates and Siding each have eight questions. Elastomeric Roofing and Built-Up Bituminous Roofing each have seven. Safety, Roofing Repairs, Sheet Metal and Flashing, and Photovoltaic Systems make up the remaining questions.
Steep roofing preparation includes asphalt shingles, wood shingles, shakes, tile, slate, metal roofing, underlayments, roof slopes, fasteners, valleys, hips, ridges, and flashing.
Roofing substrate study involves roof decks, sheathing, structural support, moisture conditions, deterioration, repairs, and preparation. Understanding the supporting roof assembly is important because the performance of roofing materials depends on what is installed beneath them.
Low-slope roofing topics include elastomeric systems and built-up bituminous roofing. Candidates should understand membranes, reinforcing materials, seams, surfacing, drainage, coatings, waterproofing, and common repair conditions.
Siding is an important part of the full C-15 classification. Students should study exterior wall materials, weather barriers, fasteners, joints, trim, soffits, and flashing connections. ASTM D4756 provides technical information related to rigid PVC siding and soffit installation.
Roofing safety is another official examination subject. Roofing contractors must recognize fall hazards, ladder risks, scaffold safety concerns, and proper use of protective equipment. OSHA construction safety references support study but are not listed as permitted C-15 trade-exam-room books.
Photovoltaic roofing systems are also included in the current examination. Students should understand the effect of rooftop solar components on roof penetrations, flashing, waterproofing, and maintenance.
Roofing Construction and Estimating is a useful supplemental study reference. It explains roof measurements, material quantities, project estimates, roofing installation methods, and repairs. Accurate estimating can help contractors improve planning and avoid costly business errors.
Contractor Exam Preps offers a Nevada C-15 Roofing and Siding Exam Book Package containing the 2018 IBC and multiple roofing, siding, safety, estimating, and photovoltaic publications. The store also offers a focused rental package with the 2018 IBC, Nevada Construction Business and Law Manual, and course access.
These products support different parts of preparation. The IBC is used for approved trade-exam code navigation. The additional roofing and siding publications are technical study resources. The Nevada business and law manual supports the separate CMS examination.
A practical six-week study plan can start with licensing rules, safety, and the IBC. The next weeks can focus on steep roofing, roof substrates, low-slope systems, roofing repairs, siding, flashing, and photovoltaic systems. Later study should include estimating and contractor business requirements.
The final preparation stage should involve full 60-question practice examinations using a two-hour time limit. Candidates should review missed questions and repeat difficult subjects.
Nevada C-15 Roofing and Siding Contractor candidates can prepare more effectively by confirming the correct license, understanding the PSI examination outline, using approved references, and studying each roofing and siding category consistently.
Explore Nevada roofing and siding study materials, NRCA references, roofing estimating books, approved code references, and contractor exam preparation products at ContractorExamPreps.com.