{"product_id":"washington-dc-journeyman-gas-pipe-fitter-highlighted-and-tabbed-book-package","title":"Washington DC Journeyman Gas Pipe Fitter - Highlighted and Tabbed Book Package","description":"\u003ch2 style=\"color: #d32f2f;\"\u003eWashington DC Journeyman Gas Pipe Fitter - Highlighted and Tabbed Book Package\u003c\/h2\u003e\u003cp\u003ePrepare for the Washington DC Journeyman Gas Pipe Fitter examination with a focused \u003cstrong\u003ehighlighted and tabbed book package\u003c\/strong\u003e built around the approved code reference identified for the exam. This package includes the \u003cstrong\u003e2012 International Fuel Gas Code\u003c\/strong\u003e, prepared with highlighting and tabs to support organized study, efficient code navigation, and faster access to important fuel-gas requirements during exam preparation.\u003c\/p\u003e\u003cp\u003eThe Washington DC Journeyman Gas Pipe Fitter examination is an \u003cstrong\u003eopen book exam\u003c\/strong\u003e. Candidates should understand fuel-gas principles while also becoming comfortable locating the applicable code provisions quickly. The highlighted and tabbed format helps organize the 2012 International Fuel Gas Code so candidates can work more efficiently with definitions, piping requirements, appliance provisions, venting rules, sizing tables, materials, and other subjects included in the examination.\u003c\/p\u003e\u003cp\u003eThe official examination is identified as the \u003cstrong\u003e301 Washington DC Journeyman Gas Pipe Fitter\u003c\/strong\u003e exam. It contains \u003cstrong\u003e50 multiple-choice questions\u003c\/strong\u003e with a \u003cstrong\u003e3-hour time limit\u003c\/strong\u003e. The published examination outline covers terminology and fundamentals, basic theory and principles, materials, appliances, venting, and pipe sizing and installation.\u003c\/p\u003e\u003cp\u003eThree major categories—Appliances, Venting, and Pipe Sizing and Installation—each represent 24% of the examination. Together, these areas make up a substantial portion of the test, making them important priorities during preparation. Candidates should still review every tested subject because general theory, terminology, fundamentals, and materials are also part of the examination.\u003c\/p\u003e\u003cp\u003eUsing a highlighted and tabbed code book can help candidates build an organized preparation routine. Tabs create visual navigation points for important sections, while highlighting makes key provisions easier to recognize during repeated review. Candidates should use the prepared book throughout their study period so its layout, major chapters, tables, and important code sections become familiar before exam day.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003ePlease allow up to 15 business days for tabbed and highlighted book package orders.\u003c\/strong\u003e\u003c\/p\u003e\u003ch2 style=\"color: #d32f2f;\"\u003eWhat You Get\u003c\/h2\u003e\u003cul\u003e  \u003cli\u003e\n\u003cstrong\u003eHighlighted and Tabbed Book: 2012 International Fuel Gas Code\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003eThe approved code reference identified for the Washington DC Journeyman Gas Pipe Fitter examination. It covers fuel-gas piping systems, pipe sizing, materials, appliances, combustion and ventilation air, chimneys, vents, definitions, installation requirements, and other provisions governing fuel-gas work.\u003c\/span\u003e\n\u003c\/li\u003e  \u003cli\u003e\n\u003cstrong\u003eHighlighted Study Material:\u003c\/strong\u003e Important portions of the code are highlighted to help candidates focus on key fuel-gas requirements during preparation.\u003c\/li\u003e  \u003cli\u003e\n\u003cstrong\u003eReference Tabs:\u003c\/strong\u003e Tabs provide visual navigation points throughout the code to help candidates reach commonly referenced chapters, tables, and subject areas more efficiently.\u003c\/li\u003e  \u003cli\u003e\n\u003cstrong\u003eJourneyman-Focused Preparation:\u003c\/strong\u003e The prepared book supports study across the major content categories identified for the Washington DC Journeyman Gas Pipe Fitter examination.\u003c\/li\u003e  \u003cli\u003e\n\u003cstrong\u003eOrder Preparation:\u003c\/strong\u003e Please allow up to 15 business days for tabbed and highlighted book package orders.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eThe highlighted and tabbed format is most useful when combined with active study. Candidates should practice locating information repeatedly, learn what each tab represents, and become familiar with the code structure rather than depending on navigation aids alone.\u003c\/p\u003e\u003ch2 style=\"color: #d32f2f;\"\u003eExam Details\u003c\/h2\u003e\u003cp\u003eThe Washington DC Journeyman Gas Pipe Fitter examination is identified as \u003cstrong\u003eExam 301\u003c\/strong\u003e. It is an open book licensing examination based on the 2012 International Fuel Gas Code and applicable trade knowledge.\u003c\/p\u003e\u003cul\u003e  \u003cli\u003e\n\u003cstrong\u003eExam:\u003c\/strong\u003e 301 Washington DC Journeyman Gas Pipe Fitter\u003c\/li\u003e  \u003cli\u003e\n\u003cstrong\u003eNumber of Questions:\u003c\/strong\u003e 50 multiple-choice questions\u003c\/li\u003e  \u003cli\u003e\n\u003cstrong\u003eTime Allowed:\u003c\/strong\u003e 3 hours\u003c\/li\u003e  \u003cli\u003e\n\u003cstrong\u003eExam Type:\u003c\/strong\u003e Open book\u003c\/li\u003e  \u003cli\u003e\n\u003cstrong\u003eApproved Code Reference:\u003c\/strong\u003e 2012 International Fuel Gas Code\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eThe published examination content outline includes:\u003c\/p\u003e\u003cul\u003e  \u003cli\u003e\n\u003cstrong\u003eTerminology and Fundamentals:\u003c\/strong\u003e 6%\u003c\/li\u003e  \u003cli\u003e\n\u003cstrong\u003eBasic Theory and Principles:\u003c\/strong\u003e 10%\u003c\/li\u003e  \u003cli\u003e\n\u003cstrong\u003eMaterials:\u003c\/strong\u003e 12%\u003c\/li\u003e  \u003cli\u003e\n\u003cstrong\u003eAppliances:\u003c\/strong\u003e 24%\u003c\/li\u003e  \u003cli\u003e\n\u003cstrong\u003eVenting:\u003c\/strong\u003e 24%\u003c\/li\u003e  \u003cli\u003e\n\u003cstrong\u003ePipe Sizing and Installation:\u003c\/strong\u003e 24%\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eAppliances, Venting, and Pipe Sizing and Installation are the three largest categories, each representing 24% of the examination. Candidates should devote substantial study time to those areas while still reviewing the supporting fundamentals and material requirements that make up the rest of the test.\u003c\/p\u003e\u003ch2 style=\"color: #d32f2f;\"\u003eOpen Book Test\u003c\/h2\u003e\u003cp\u003eThe Washington DC Journeyman Gas Pipe Fitter examination is an \u003cstrong\u003eopen book test\u003c\/strong\u003e. The \u003cstrong\u003e2012 International Fuel Gas Code\u003c\/strong\u003e is identified as the approved reference for the exam.\u003c\/p\u003e\u003cp\u003eAn open book format does not eliminate the need for preparation. Candidates have three hours to answer 50 questions, and some items may require code lookup, table navigation, interpretation of installation requirements, or pipe-sizing work. Efficient reference use can help preserve valuable testing time.\u003c\/p\u003e\u003cp\u003eThe highlighted and tabbed book can support this process by creating recognizable locations throughout the code. Tabs help candidates move more quickly between chapters, while highlighting makes important information easier to identify once the correct section is reached.\u003c\/p\u003e\u003cp\u003eA productive approach is to identify the subject of a question before opening the book. Determine whether the problem involves pipe sizing, appliance installation, venting, materials, theory, or terminology. Then move directly to the most relevant chapter, section, table, or definition.\u003c\/p\u003e\u003cp\u003eCandidates should also practice reading code provisions completely. Fuel-gas rules may include exceptions, table notes, installation conditions, cross-references, and definitions that affect the correct answer. Stopping after finding one familiar phrase can lead to mistakes if additional conditions apply.\u003c\/p\u003e\u003ch2 style=\"color: #d32f2f;\"\u003eLicensing Steps\u003c\/h2\u003e\u003cp\u003eWashington DC gasfitting licenses are regulated through the \u003cstrong\u003eDistrict of Columbia Board of Industrial Trades\u003c\/strong\u003e. Journeyman applicants using the examination pathway must meet the applicable experience and documentation requirements before sitting for the exam.\u003c\/p\u003e\u003col\u003e  \u003cli\u003e\n\u003cstrong\u003eAccumulate qualifying gasfitting experience.\u003c\/strong\u003e Journeyman applicants using the examination pathway must document the required amount of work experience.\u003c\/li\u003e  \u003cli\u003e\n\u003cstrong\u003ePrepare employment verification.\u003c\/strong\u003e Applicants must provide employment verification supporting the length and nature of their qualifying experience.\u003c\/li\u003e  \u003cli\u003e\n\u003cstrong\u003ePrepare supporting tax records.\u003c\/strong\u003e Journeyman applicants using the examination pathway are required to provide tax records along with employment verification.\u003c\/li\u003e  \u003cli\u003e\n\u003cstrong\u003eSubmit the licensing application.\u003c\/strong\u003e Complete the applicable District occupational and professional licensing application with the required supporting documentation.\u003c\/li\u003e  \u003cli\u003e\n\u003cstrong\u003eEstablish examination eligibility.\u003c\/strong\u003e Candidates must show the appropriate amount of qualifying experience before sitting for the examination.\u003c\/li\u003e  \u003cli\u003e\n\u003cstrong\u003eSchedule the examination.\u003c\/strong\u003e Eligible candidates complete the Washington DC Journeyman Gas Pipe Fitter examination scheduling process through the authorized testing provider.\u003c\/li\u003e  \u003cli\u003e\n\u003cstrong\u003ePrepare using the approved code.\u003c\/strong\u003e Study the 2012 International Fuel Gas Code while practicing pipe sizing, appliance questions, venting, materials, and code navigation.\u003c\/li\u003e  \u003cli\u003e\n\u003cstrong\u003eTake the open book exam.\u003c\/strong\u003e Complete the 50-question examination within the 3-hour testing period.\u003c\/li\u003e  \u003cli\u003e\n\u003cstrong\u003eComplete remaining licensing requirements.\u003c\/strong\u003e Follow the District's licensing process after satisfying the examination and other applicable requirements.\u003c\/li\u003e\n\u003c\/ol\u003e\u003cp\u003eThe District also recognizes an examination-waiver pathway for individuals who provide acceptable proof of completion of a nationally certified apprenticeship program. Applicants using that pathway must provide the applicable completion documentation.\u003c\/p\u003e\u003ch2 style=\"color: #d32f2f;\"\u003eState Requirements\u003c\/h2\u003e\u003cp\u003eWashington DC offers licensing classifications for \u003cstrong\u003eplumbing, gasfitting, and combined plumbing and gasfitting work\u003c\/strong\u003e. The Journeyman Gas Pipe Fitter examination is associated specifically with the gasfitting trade.\u003c\/p\u003e\u003cp\u003eFor a Journeyman applicant using the examination pathway, the District identifies an experience requirement of \u003cstrong\u003e4 years or 8,000 work hours\u003c\/strong\u003e. Applicants must provide \u003cstrong\u003etax records and an employment verification letter\u003c\/strong\u003e documenting the qualifying work experience.\u003c\/p\u003e\u003cp\u003eThe District requires applicants to demonstrate the appropriate amount of experience before sitting for the examination. Employment verification letters should detail the length of employment and the experience gained and should be signed by the appropriate master tradesperson.\u003c\/p\u003e\u003cp\u003eApplicants who have completed a nationally certified apprenticeship program may qualify to waive the Journeyman examination when acceptable proof of completion is provided. Supporting documentation can include an apprenticeship certification of completion, a formal designation certificate, or official transcripts.\u003c\/p\u003e\u003cp\u003eWashington DC plumbing and gasfitting licenses expire on March 31 of even-numbered years under the District's current licensing framework. Candidates pursuing the Journeyman Gas Pipe Fitter license should follow the applicable District licensing process in addition to working toward the examination.\u003c\/p\u003e\u003ch2 style=\"color: #d32f2f;\"\u003eReference Books\u003c\/h2\u003e\u003cul\u003e  \u003cli\u003e\n\u003cstrong\u003e2012 International Fuel Gas Code\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003eThe 2012 International Fuel Gas Code is the approved code reference identified for the Washington DC Journeyman Gas Pipe Fitter examination. It addresses fuel-gas piping systems, materials, pipe sizing, appliance installation, combustion and ventilation air, vents, chimneys, definitions, general requirements, and other provisions affecting fuel-gas installations. This package includes the book in highlighted and tabbed format.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eThe International Fuel Gas Code should be used throughout preparation rather than reserved only for test day. Repeated reference work can help candidates become more comfortable with definitions, chapter organization, piping tables, venting requirements, appliance provisions, and material requirements.\u003c\/p\u003e\u003cp\u003eFamiliarity with the code can also reduce the amount of time spent using the index. The index remains a useful tool, but candidates who already know approximately where major subjects are located can often move through the book more efficiently.\u003c\/p\u003e\u003ch2 style=\"color: #d32f2f;\"\u003eExam Room Approved Books\u003c\/h2\u003e\u003cul\u003e  \u003cli\u003e\n\u003cstrong\u003e2012 International Fuel Gas Code\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003eThe 2012 International Fuel Gas Code is identified as the approved reference for the Washington DC Journeyman Gas Pipe Fitter open book examination.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eThis highlighted and tabbed package is built around the code reference identified for the examination. Candidates should practice using the prepared book well before test day so the tabs, highlighting, major tables, and overall organization are already familiar.\u003c\/p\u003e\u003ch2 style=\"color: #d32f2f;\"\u003eTest Information and Exam resources\u003c\/h2\u003e\u003cp\u003e\u003cstrong\u003eTerminology and Fundamentals:\u003c\/strong\u003e Review definitions and the basic terminology used throughout the International Fuel Gas Code. Exact definitions matter because the meaning assigned to a term can determine which installation requirement applies.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eBasic Theory and Principles:\u003c\/strong\u003e Study fuel-gas fundamentals, including pressure, flow, combustion principles, system operation, demand, and the relationship between the gas supply and connected appliances. Understanding the theory behind the system can help candidates interpret code questions more accurately.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eMaterials:\u003c\/strong\u003e Materials represent 12% of the examination. Review permitted piping materials, fittings, joints, valves, connectors, and other components used in fuel-gas systems. Candidates should understand where specific materials may be used and what installation limitations apply.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eAppliances:\u003c\/strong\u003e Appliances account for 24% of the examination. Review gas-fired appliance installation, location, clearances, connections, combustion and ventilation air, shutoff requirements, access, and other code provisions affecting appliance installations.\u003c\/p\u003e\u003cp\u003eAppliance questions may require more than memorizing a single requirement. Candidates should practice identifying the type of appliance, the installation conditions, and any related requirements involving clearances, combustion air, venting, or gas supply.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eVenting:\u003c\/strong\u003e Venting represents another 24% of the examination. Review vents, chimneys, vent connectors, termination requirements, sizing concepts, appliance venting, installation methods, and other provisions designed to safely remove combustion products.\u003c\/p\u003e\u003cp\u003eCandidates should understand the difference between vent types and become familiar with where venting tables and installation requirements are located. Venting questions can involve both code navigation and careful interpretation of installation conditions.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003ePipe Sizing and Installation:\u003c\/strong\u003e This category also represents 24% of the examination. Study fuel-gas piping systems, developed length, appliance demand, sizing methods, system pressure, installation requirements, shutoff valves, piping supports, protection, and related code provisions.\u003c\/p\u003e\u003cp\u003ePipe-sizing questions are especially useful for timed practice. Start by identifying the system conditions, then select the correct sizing table. Read the table heading and notes carefully, determine the appropriate developed length, identify the required demand, and choose the applicable pipe size.\u003c\/p\u003e\u003cp\u003eA common mistake in fuel-gas exam preparation is to memorize a handful of pipe sizes without understanding the sizing method. Instead, practice using the tables from the beginning of the problem to the final answer. This develops a process that can be applied even when the numbers or system configuration change.\u003c\/p\u003e\u003cp\u003eAnother useful study strategy is to connect appliance questions with pipe-sizing and venting requirements. In real installations, these subjects are related, and examination questions may require candidates to understand how an appliance affects gas demand, piping, combustion air, and venting.\u003c\/p\u003e\u003cp\u003eTimed practice can reveal where additional preparation is needed. If a candidate takes too long to locate venting tables or material requirements, those sections can receive extra review. If pipe-sizing errors occur because the wrong table is selected, focus on identifying table conditions before working calculations.\u003c\/p\u003e\u003cp\u003eThe highlighted and tabbed book supports this process by making major subjects easier to recognize. Candidates should still understand the surrounding code so the visual navigation aids reinforce knowledge rather than replace it.\u003c\/p\u003e\u003ch2 style=\"color: #d32f2f;\"\u003eHow 1 Exam Prep Helps You Reach Your Goal\u003c\/h2\u003e\u003cp\u003e1 Exam Prep helps Washington DC Journeyman Gas Pipe Fitter candidates organize their preparation around the approved code reference and the actual subject areas included on the examination.\u003c\/p\u003e\u003cp\u003eThis highlighted and tabbed package includes a prepared \u003cstrong\u003e2012 International Fuel Gas Code\u003c\/strong\u003e designed to support structured study and efficient reference navigation. Tabs create recognizable locations throughout the book, while highlighting helps important provisions stand out during repeated review.\u003c\/p\u003e\u003cp\u003e1 Exam Prep encourages candidates to study by content area instead of reading the code without a plan. Start with the published examination outline and build a study rotation around terminology, theory, materials, appliances, venting, and pipe sizing.\u003c\/p\u003e\u003cp\u003eBecause Appliances, Venting, and Pipe Sizing and Installation each account for 24% of the examination, candidates can devote substantial attention to those areas while continuing to review supporting fundamentals and materials.\u003c\/p\u003e\u003cp\u003eReference navigation should also be practiced regularly. Identify the subject of the question, move to the applicable part of the code, locate the controlling section or table, and confirm the answer based on the complete requirement.\u003c\/p\u003e\u003cp\u003ePractice-oriented preparation can help strengthen pipe-sizing skills, code interpretation, appliance knowledge, and venting-system understanding. Experienced gasfitters can also connect practical field experience with the precise terminology and requirements used in the code.\u003c\/p\u003e\u003cp\u003eThe goal is to build confidence through an organized study routine, stronger trade knowledge, and repeated use of the approved reference. The highlighted and tabbed format includes a practical foundation for that preparation.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003ePlease allow up to 15 business days for tabbed and highlighted book package orders.\u003c\/strong\u003e\u003c\/p\u003e\u003ch2 style=\"color: #d32f2f;\"\u003eFrequently Asked Questions\u003c\/h2\u003e\u003ch2 style=\"color: #d32f2f;\"\u003eIs the Washington DC Journeyman Gas Pipe Fitter exam open book?\u003c\/h2\u003e\u003cp\u003eYes. The Washington DC Journeyman Gas Pipe Fitter examination is an \u003cstrong\u003eopen book exam\u003c\/strong\u003e.\u003c\/p\u003e\u003ch2 style=\"color: #d32f2f;\"\u003eWhat book is included in this package?\u003c\/h2\u003e\u003cp\u003eThis package includes the \u003cstrong\u003e2012 International Fuel Gas Code\u003c\/strong\u003e in highlighted and tabbed format.\u003c\/p\u003e\u003ch2 style=\"color: #d32f2f;\"\u003eHow long does a highlighted and tabbed book package order take?\u003c\/h2\u003e\u003cp\u003ePlease allow up to \u003cstrong\u003e15 business days\u003c\/strong\u003e for tabbed and highlighted book package orders.\u003c\/p\u003e\u003ch2 style=\"color: #d32f2f;\"\u003eHow many questions are on the Washington DC Journeyman Gas Pipe Fitter exam?\u003c\/h2\u003e\u003cp\u003eThe examination contains \u003cstrong\u003e50 multiple-choice questions\u003c\/strong\u003e.\u003c\/p\u003e\u003ch2 style=\"color: #d32f2f;\"\u003eHow much time is allowed for the examination?\u003c\/h2\u003e\u003cp\u003eCandidates have \u003cstrong\u003e3 hours\u003c\/strong\u003e to complete the Washington DC Journeyman Gas Pipe Fitter examination.\u003c\/p\u003e\u003ch2 style=\"color: #d32f2f;\"\u003eWhich code is used for the Journeyman Gas Pipe Fitter exam?\u003c\/h2\u003e\u003cp\u003eThe \u003cstrong\u003e2012 International Fuel Gas Code\u003c\/strong\u003e is identified as the approved code reference for the examination.\u003c\/p\u003e\u003ch2 style=\"color: #d32f2f;\"\u003eWhat are the largest content areas on the exam?\u003c\/h2\u003e\u003cp\u003eAppliances, Venting, and Pipe Sizing and Installation each represent \u003cstrong\u003e24%\u003c\/strong\u003e of the published examination outline.\u003c\/p\u003e\u003ch2 style=\"color: #d32f2f;\"\u003eWhat other subjects are tested?\u003c\/h2\u003e\u003cp\u003eThe examination also covers Terminology and Fundamentals, Basic Theory and Principles, and Materials.\u003c\/p\u003e\u003ch2 style=\"color: #d32f2f;\"\u003eHow much experience is required for Journeyman licensure by examination?\u003c\/h2\u003e\u003cp\u003eThe District identifies \u003cstrong\u003e4 years or 8,000 work hours\u003c\/strong\u003e of qualifying experience for Journeyman applicants using the examination pathway.\u003c\/p\u003e\u003ch2 style=\"color: #d32f2f;\"\u003eWhat documents are required to verify experience?\u003c\/h2\u003e\u003cp\u003eJourneyman applicants using the examination pathway must provide tax records and an employment verification letter documenting qualifying trade experience.\u003c\/p\u003e\u003ch2 style=\"color: #d32f2f;\"\u003eCan the Journeyman examination be waived?\u003c\/h2\u003e\u003cp\u003eApplicants who provide acceptable proof of completion of a nationally certified apprenticeship program may qualify to waive the Journeyman examination under the District's licensing process.\u003c\/p\u003e\u003ch2 style=\"color: #d32f2f;\"\u003eWhy use a highlighted and tabbed fuel gas code?\u003c\/h2\u003e\u003cp\u003eHighlighting helps important information stand out during study, while tabs provide navigation points throughout the code. Regular practice with the prepared book can make important chapters, tables, and requirements easier to locate.\u003c\/p\u003e\u003ch2 style=\"color: #d32f2f;\"\u003eShould I study even though the exam is open book?\u003c\/h2\u003e\u003cp\u003eYes. Open book access is most useful when candidates already understand the major concepts and know approximately where information is located. Efficient code navigation can save time during a 50-question examination.\u003c\/p\u003e\u003ch2 style=\"color: #d32f2f;\"\u003eHow should I prepare for pipe-sizing questions?\u003c\/h2\u003e\u003cp\u003ePractice identifying the applicable sizing table, reading table notes, determining developed length and system demand, and selecting the correct pipe size based on the conditions provided.\u003c\/p\u003e\u003ch2 style=\"color: #d32f2f;\"\u003eHow should I prepare for appliance and venting questions?\u003c\/h2\u003e\u003cp\u003eReview appliance installation requirements, combustion air, clearances, connections, vent systems, chimneys, vent connectors, termination requirements, and the applicable fuel-gas code provisions. Practice locating those requirements under timed conditions.\u003c\/p\u003e","brand":"Contractor Exam Preps","offers":[{"title":"Default Title","offer_id":67919743844405,"sku":"OEP-884384313","price":195.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2522\/1688\/files\/DC-JOURNEYMANGASFITTER-HT.jpg?v=1794040746","url":"https:\/\/contractorexampreps.com\/products\/washington-dc-journeyman-gas-pipe-fitter-highlighted-and-tabbed-book-package","provider":"Contractor Exam Preps","version":"1.0","type":"link"}