{"product_id":"arizona-b-3-cr-61-limited-remodeling-and-repair-contractor-residential-commercial-certification-package","title":"Arizona B-3 (CR-61) Limited Remodeling and Repair Contractor Exam (Residential\/Commercial) Book Package","description":"\u003ch1 style=\"text-align: center; color: #000;\"\u003eARIZONA B-3 (CR-61) LIMITED REMODELING AND REPAIR CONTRACTOR EXAM (RESIDENTIAL\/COMMERCIAL) BOOK PACKAGE\u003c\/h1\u003e\n\u003cp style=\"text-align: center;\"\u003eThe Arizona B-3 (CR-61) Limited Remodeling and Repair Contractor Exam Book Package, offered by Contractor Exam Preps, is structured to assist applicants seeking licensure through the Arizona Registrar of Contractors (ROC). This credential authorizes work on residential and commercial projects involving limited remodeling, repair, and improvement within existing structures. The package includes essential references such as the Arizona Contractor’s License Law, the NASCLA Contractor’s Guide to Business, Law, and Project Management – Arizona Edition, and selected trade manuals covering residential and commercial renovation standards. Designed in alignment with PSI test vendor requirements, this prep set provides full coverage of the Business Management and trade sections, ensuring compliance with ROC exam scopes and the National Association of State Contractors Licensing Agencies (NASCLA) exam standards.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch1\u003e\u003cbr\u003e\u003c\/h1\u003e\n\u003ch3\u003eThe first 3 books may be brought into the PSI exam center, the last 10 may not.\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eThis book package is for all 13 books\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe following reference material \u003cstrong\u003eis allowed\u003c\/strong\u003e in the examination center:\u003c\/p\u003e\n\u003cp\u003eCode of Federal Regulations - 29 CFR Part 1926 (OSHA)\u003c\/p\u003e\n\u003cp\u003eInternational Residential Code for One- and Two-Family Dwellings, 2018\u003c\/p\u003e\n\u003cp\u003eInternational Building Code, 2018\u003c\/p\u003e\n\u003cp\u003eThe following reference material is \u003cstrong\u003enot allowed\u003c\/strong\u003e in the examination center\u003c\/p\u003e\n\u003cp\u003ePipe and Excavation Contracting\u003c\/p\u003e\n\u003cp\u003eCarpentry and Building Construction, 2016\u003c\/p\u003e\n\u003cp\u003eContractors Guide to Quality Concrete Construction, 3rd Edition, 2005\u003c\/p\u003e\n\u003cp\u003eModern Masonry - Brick, Block, Stone, 10th Edition\u003c\/p\u003e\n\u003cp\u003eRoofing Construction \u0026amp; Estimating\u003c\/p\u003e\n\u003cp\u003eWalker's Insulation Techniques and Estimating Handbook\u003c\/p\u003e\n\u003cp\u003ePDCA Craftsman's Manual and Textbook, Eighth Edition,\u003c\/p\u003e\n\u003cp\u003eStandard Practice for Installation of Rigid Poly Vinyl Chloride\u003c\/p\u003e\n\u003cp\u003eGypsum Construction Handbook, 7th edition, 2014\u003c\/p\u003e\n\u003cp\u003eHandbook for Ceramic, Glass, and Stone Tile Installation, 2017\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003eSCOPE OF WORK \u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003eRemodeling and repairs to existing structures or appurtenances, excluding swimming pools or spas, not to exceed $25,000 per project per dwelling. Work on electrical, plumbing, air conditioning systems, or boilers that require a building permit must be subcontracted to an appropriately licensed contractor. The scope of work allowed under the CR-7R carpentry classification is included. Doors, Gates, Windows, and Accessories, Removable Formwork and shoring, Nailing and Stapling. \u003cbr data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003eAll rough and finish general carpentry work on new and existing structures, including installation of related hardware and accessories, without dollar limitation. All general remodeling, additions, replacements, and repairs to existing structures, and pre-manufactured items on existing structures, except electrical, plumbing, and air conditioning system work which shall be sublet to properly licensed contractors. A single contract for remodeling, repair or a combination of both, shall not exceed $50,000. \u003cbr data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003eRemodeling or repair of an existing residential structure or appurtenance except for electrical, plumbing, mechanical, boilers, swimming pools, or spas which must be subcontracted to an appropriately licensed contractor. The scope of work allowed under the C-7 carpentry classification is included within this scope. Doors, Gates, Windows, and Accessories, Removable Formwork and shoring, Nailing and Stapling. The trade test is considered equivalent for these classifications and upon passing the CBME and trade exam, any of these license classification may be applied for without further testing.\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003ethe exam is 75 questions taken over 180 minutes. The minimum required score to pass is a 70%.\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003eThe reference material listed above was used to prepare the questions for this examination. The examination may also contain questions based on trade knowledge or general industry practices. Except for Code books, you can base your answers on later editions of references as they become available. For Code questions, the examinations will be based only on the edition of the Code book that is listed.\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003eCandidates may use a silent, nonprinting, non-programmable calculator in the examination center.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e","brand":"brown-states","offers":[{"title":"Default Title","offer_id":45014862397493,"sku":"19021219561529","price":1304.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2522\/1688\/files\/arizona_1024x1024_2x_16f62ef6-ce75-4e54-87d7-bc61bb6d381e.png?v=1772081980","url":"https:\/\/contractorexampreps.com\/products\/arizona-b-3-cr-61-limited-remodeling-and-repair-contractor-residential-commercial-certification-package","provider":"Contractor Exam Preps","version":"1.0","type":"link"}